Power House Series
A First in the Industry
- Displays Rich of parameters in 8 digit 8 row LCD display.
- 3 frozen parameters with 2 programmable to VLL/ VLN / Current / Watts / PF
- Sleep mode. Backlight is the most power consumption part. It reduces the backlight Intensity after 1 Minutes.
- Continuous Wh display even in Auto scrolling mode.
- Displays ON hours, Load hours & Number of interruption.
- Graphical Display - Future up-gradation option.
- Neutral Current Display, RPM Measurements
- Analog input option for Process integration.
- Digital Input option for Automation or cost effective networking.
- Digital Output with programmable trip time option for protection / control application.
- Demands Control Option - 4 relay in compact size 96×96×45 mm.
Smart & Intelligent
- True RMS measurement.
- Accuracy Class 1.0 IEC 61036 / CBIP 88 (0.5, 0.2 Option)
- User Programmable Password Protection
- Auto-scaling of Kilo, Mega, Giga and Decimal Point
- Finger Touch Proof Terminals for Voltage and Current Connections
- Clearance & Creepage distance meets UL 508 safety standard.
- Built-in Voltage & Current Phase Analyzer Measures 4 Quadrant Power & Energy (4 Quadrant Energy for R/D Option)
- Auto Scrolling
- Communication with PCs, PLCs, DCS thru Optional RS 485/RS 232 Serial Interfaces.
PH 7700 Demand Monitor / Controller
- RTC synchronization with EB meters
- Demand Monitor Option - Sliding or Fixed Window
- Programmable Demand Period (5min to 30Min. in steps of 1 Min.)
- Programmable Forecast Time (5min to 15Min. in steps of 1 Min.)
- Field Programmable Watts Demand (or) VA Demand (or) Amps Demand
- Field Programmable Forecast Demand or Independent Step Demand Control
- View Present Demand, Forecast Demand, Maximum Demand and Additional load on single page
MPS 8000 - Motor Protection System*
- Single solutions for protection of meters against voltage, overload, frequency, PF, single phasing,
- Unbalance loading of voltage or current, phase reversal.
- Programmable start time from sensing healthy condition.
- Programmable trip time for volts/overload/Hz/PF
- Clamp on T meters/5A option for easy installation without shutdown
- Programmable relay status High or Low for safe, 2 relay for alarm and trip.
- Store the reasons for trapping future correction
- Manual re-correction once trapped measures VLL, VLN, A, Hz, W, VA, PF, Wh, Load hours, ON time,
- No. of interruption, Healthy/board or line/Unhealthy indication for on time view
- DIN Rail option
- RS485/232 connection option
- Alarm region for analysis
* will be released on February 2008
|