Multi-Function Meters

Tiny Master Series

Unique Features
TM 3420
  • Wide product spectrum to suit customer requirement. True RMS measurements
  • 4 row display. Hence Total/Average & phase wise readings displayed in single page. Maximum info in single page. This helps to cross verify and determine power quality loading pattern etc
  • Measure 4 quadrant power and energy
  • Simultaneous sampling of voltage and current signals ensures better accuracy
  • Easy installation and user programmability. User friendly and simple navigation method. Reduced operational hassles
  • Higher CT/PT ratio programmability. Current primary up to 99kA & Voltage primary up to 999kV provides wide range of usability
  • Larger Full scale programmability Up to 2000 MVA
  • Optional RS232 option. Data downloading is simpler by connecting the meter directly to the PC
  • Auto scaling and selectable Auto scrolling mode
  • Single Phase configuration. Meter provides greater flexibility and wider range of usability
  • OLD Register to store last cleared integrator data (Energy) and Load hours
  • User Programmable password. Higher security protection
  • Displays calculated Neutral current. Helps to determine power quality
  • Wider range and universal auxiliary supply: 80 to 300V AC or DC. Also 48V DC optional feature
  • Smart parameter grouping and powerful features
  • 4 basic or 4 power or 2 energy readings can be read in single page of display. 4 Energy readings in single page in model TM 7400. Lesser operational hassles.
  • Pre-determined integrator overflows value
  • Separate LOAD HOURS pages for Received, Delivered*, OLD (*available in meter having received / delivered option)
  • Selectable VA measurement Vector/Scalar/Vector Harmonics
  • Transducer version is also available
  • Demand control option in smallest size with four relay output
  • Up gradation facility
    - Upgradeable to higher versions
    - Upgradeable to additional features (RS 485, R/D, Digital input/output etc)
TM 1400 (Basic Pack)
  • Displays more than 20 Basic parameters
  • Simultaneous display of Average VLL, VLN, Amps, Hz or Average and Phase wise parameters in a single page
  • VLL, VLN, Current Average and Phase wise
  • Voltage and Current Phase Angles
  • Neutral Current Display
  • Generator RPM Measurements
TM 2400 (Power Pack)
  • Displays more than 11 Power parameters
  • Simultaneous display of Average W, VA, PF, VAr or Average and Phase wise parameters in a single page
  • Watts Total and Phase wise
  • VAr Total and Phase wise
  • PF Average and Phase wise
  • VA Total and Phase wise
  • Generator RPM Measurements
TM 3400 (Energy Pack)
  • Simultaneous display of two Energy in a single page (Wh, VAh or VArh Inductive and Capacitive)
  • 8 Digit resolution for each Energy
  • Received / Delivered (Import/Export) Energy option
  • Separate Load hours for Received, Delivered and Net
  • OLD register to store previously cleared Energy values and Load hours
TM 4400 (Basic + Power) = TM 1400 + TM 2400
  • Displays more than 25 Basic and Power parameters
  • Simultaneous display of Average Basic (VLL, VLN, Amps, Hz.) or Total Power (W, VA, PF, VAr) Parameters or Average/Total and Phase wise of instantaneous parameters
  • Generator RPM Measurements
  • Quick & Easy Navigation and programming
TM 5400 (Power + Energy) = TM 2400 + TM 3400
  • Displays all Power and Energy parameters
  • Simultaneous display of all Power parameters (W, VA, PF, VAr) or Total and phase wise of power Parameters or 2 energy(Wh, VAh or VArh inductive, capacitive)
  • Received/Delivered (Import/Export) energy option
  • Separate Load hours for Received, Delivered and Net
  • OLD Registers to store the previously cleared Energy values and Load hours
TM 7400 (Master Pack) = TM 1400 + TM 5400
  • Displays more than 75 parameters
  • Simultaneous display of VLL, VLN, Amps, Hz or W, VA, VAr, PF or Wh, VAh, VArh Inductive, VArh Capacitive in a single page
  • Analog Voltage Input (0-1V)/Current Input (0-20mA or 4-20mA) programmable to any Full Scale value (Optional)
  • Digital Outputs (4 potential free contacts optional)
  • Generator RPM Measurements
TM 3410 (Textile Pack)
  • Specially designed for Textile Applications
  • Displays Amps and PF Average and Phase wise
  • Wh and VAh in the single page and each with 8 digit Resolution
  • Neutral current display
  • Current phase Angle
  • OLD Registers to store the previously cleared Energy values
  • Yarn count information programmable/communicatable
TM 5410 (Gen Pack)
  • Displays more than 50 parameters
  • Specially designed for Gen set Applications
  • Displays VLL, VLN, A Average and Phase wise, Frequency
  • Voltage and Current Phase Angles. W, PF Total and Phase wise
  • Wh and VAh in the single page and each with 8 digit Resolution
  • Freeze Display through keys (Optional)
  • OLD registers to store the previously cleared Energy values
  • Generator RPM & Load hours Measurements
TM 3420 (Dual Energy)
  • Directly Replaces Two Energy Meters
  • Requires only potential free contact from AMF
  • Option of Accumulation in alternate registers if VLL/ Amps/ Frequency/ Watts/ VA/ PF is more than the set (Hurdle) value
  • Relay output option based on set value
  • Individual Load hours for main and Alternate registers (Eg.: EB or Gen) for effective utilisation study
Digital Outputs (Up to 4 relay Outputs)
  • 4 User Defined Optional Potential Free Contact based on threshold setting
  • Protection Relay for any of under/over voltage/Current/Frequency, Phase missing, W, VA, PF and Wh
  • Programmable trip time 1 to 50 sec to suit different load conditions
  • Rating of Control Relays: NO contact SPST. 250VAC / 30VDC @ 2 Amps, resistive
Applications
  • Automatic connection or disconnection of Gen sets supply to Common bus
  • Protection of equipment from Under/Over Voltage or Current or Frequency
  • Protection of 3 phase equipment from Phase missing, Over load etc
Digital Inputs (Up to 4 Inputs)
  • Accept 4 digital inputs (internal excitation)
  • Min Pulse Width: 50msec
  • Min Duration of successive pulse: 100msec
  • Input impedance: 50kohm
Applications
  • Cost effective network
  • Avoid PLC or Data concentrator for networking
  • Reduces wiring complexity by 1/4th
Analog Input (Up to 2 Inputs)
  • Accept Analog Current inputs 0 to 20mA or 4 to 20mA
  • Accept Analog voltage inputs 0-1V DC
  • Programmable for any Full scale and Offset. Accuracy: 2%
Applications
  • Process parameters like Temperature, Pressure, RPM etc., which has 4 -20mA or 0 -20mA output, can be integrated and communicated.
  • Single meter solutions for Genset data like Oil level, Temperature with Electrical parameter
Downloads
Product Catalog
Energy Management System (1 MB)
Demand Controller (281 KB)
Power House Series (292 KB)
Tiny Master Series (123 KB)
Little Genius Series (144 KB)
Alpha Series (157 KB)
Protection Devices (238 KB)
Technical Specifications (102 KB)
Programming Guides
Demand Controller (662 KB)
Power House Series (602 KB)
Tiny Master Series (339 KB)
Little Genius 3Row Series (269 KB)
Little Genius & Micro Genius Series (256 KB)
Modbus Comm Register Map (19 KB)
Alpha Series (115 KB)