Multi-Function Meters
Tiny Master Series
Unique Features

- Wide product spectrum to suit customer requirement. True RMS measurements
- 4 row display. Hence Total/Average & phase wise readings displayed in single page. Maximum info in single page. This helps to cross verify and determine power quality loading pattern etc
- Measure 4 quadrant power and energy
- Simultaneous sampling of voltage and current signals ensures better accuracy
- Easy installation and user programmability. User friendly and simple navigation method. Reduced operational hassles
- Higher CT/PT ratio programmability. Current primary up to 99kA & Voltage primary up to 999kV provides wide range of usability
- Larger Full scale programmability Up to 2000 MVA
- Optional RS232 option. Data downloading is simpler by connecting the meter directly to the PC
- Auto scaling and selectable Auto scrolling mode
- Single Phase configuration. Meter provides greater flexibility and wider range of usability
- OLD Register to store last cleared integrator data (Energy) and Load hours
- User Programmable password. Higher security protection
- Displays calculated Neutral current. Helps to determine power quality
- Wider range and universal auxiliary supply: 80 to 300V AC or DC. Also 48V DC optional feature
- Smart parameter grouping and powerful features
- 4 basic or 4 power or 2 energy readings can be read in single page of display. 4 Energy readings in single page in model TM 7400. Lesser operational hassles.
- Pre-determined integrator overflows value
- Separate LOAD HOURS pages for Received, Delivered*, OLD (*available in meter having received / delivered option)
- Selectable VA measurement Vector/Scalar/Vector Harmonics
- Transducer version is also available
- Demand control option in smallest size with four relay output
- Up gradation facility
- Upgradeable to higher versions
- Upgradeable to additional features (RS 485, R/D, Digital input/output etc)
TM 1400 (Basic Pack)
- Displays more than 20 Basic parameters
- Simultaneous display of Average VLL, VLN, Amps, Hz or Average and Phase wise parameters in a single page
- VLL, VLN, Current Average and Phase wise
- Voltage and Current Phase Angles
- Neutral Current Display
- Generator RPM Measurements
TM 2400 (Power Pack)
- Displays more than 11 Power parameters
- Simultaneous display of Average W, VA, PF, VAr or Average and Phase wise parameters in a single page
- Watts Total and Phase wise
- VAr Total and Phase wise
- PF Average and Phase wise
- VA Total and Phase wise
- Generator RPM Measurements
TM 3400 (Energy Pack)
- Simultaneous display of two Energy in a single page (Wh, VAh or VArh Inductive and Capacitive)
- 8 Digit resolution for each Energy
- Received / Delivered (Import/Export) Energy option
- Separate Load hours for Received, Delivered and Net
- OLD register to store previously cleared Energy values and Load hours
TM 4400 (Basic + Power) = TM 1400 + TM 2400
- Displays more than 25 Basic and Power parameters
- Simultaneous display of Average Basic (VLL, VLN, Amps, Hz.) or Total Power (W, VA, PF, VAr) Parameters or Average/Total and Phase wise of instantaneous parameters
- Generator RPM Measurements
- Quick & Easy Navigation and programming
TM 5400 (Power + Energy) = TM 2400 + TM 3400
- Displays all Power and Energy parameters
- Simultaneous display of all Power parameters (W, VA, PF, VAr) or Total and phase wise of power Parameters or 2 energy(Wh, VAh or VArh inductive, capacitive)
- Received/Delivered (Import/Export) energy option
- Separate Load hours for Received, Delivered and Net
- OLD Registers to store the previously cleared Energy values and Load hours
TM 7400 (Master Pack) = TM 1400 + TM 5400
- Displays more than 75 parameters
- Simultaneous display of VLL, VLN, Amps, Hz or W, VA, VAr, PF or Wh, VAh, VArh Inductive, VArh Capacitive in a single page
- Analog Voltage Input (0-1V)/Current Input (0-20mA or 4-20mA) programmable to any Full Scale value (Optional)
- Digital Outputs (4 potential free contacts optional)
- Generator RPM Measurements
TM 3410 (Textile Pack)
- Specially designed for Textile Applications
- Displays Amps and PF Average and Phase wise
- Wh and VAh in the single page and each with 8 digit Resolution
- Neutral current display
- Current phase Angle
- OLD Registers to store the previously cleared Energy values
- Yarn count information programmable/communicatable
TM 5410 (Gen Pack)
- Displays more than 50 parameters
- Specially designed for Gen set Applications
- Displays VLL, VLN, A Average and Phase wise, Frequency
- Voltage and Current Phase Angles. W, PF Total and Phase wise
- Wh and VAh in the single page and each with 8 digit Resolution
- Freeze Display through keys (Optional)
- OLD registers to store the previously cleared Energy values
- Generator RPM & Load hours Measurements
TM 3420 (Dual Energy)
- Directly Replaces Two Energy Meters
- Requires only potential free contact from AMF
- Option of Accumulation in alternate registers if VLL/ Amps/ Frequency/ Watts/ VA/ PF is more than the set (Hurdle) value
- Relay output option based on set value
- Individual Load hours for main and Alternate registers (Eg.: EB or Gen) for effective utilisation study
Digital Outputs (Up to 4 relay Outputs)
- 4 User Defined Optional Potential Free Contact based on threshold setting
- Protection Relay for any of under/over voltage/Current/Frequency, Phase missing, W, VA, PF and Wh
- Programmable trip time 1 to 50 sec to suit different load conditions
- Rating of Control Relays: NO contact SPST. 250VAC / 30VDC @ 2 Amps, resistive
Applications
- Automatic connection or disconnection of Gen sets supply to Common bus
- Protection of equipment from Under/Over Voltage or Current or Frequency
- Protection of 3 phase equipment from Phase missing, Over load etc
Digital Inputs (Up to 4 Inputs)
- Accept 4 digital inputs (internal excitation)
- Min Pulse Width: 50msec
- Min Duration of successive pulse: 100msec
- Input impedance: 50kohm
Applications
- Cost effective network
- Avoid PLC or Data concentrator for networking
- Reduces wiring complexity by 1/4th
Analog Input (Up to 2 Inputs)
- Accept Analog Current inputs 0 to 20mA or 4 to 20mA
- Accept Analog voltage inputs 0-1V DC
- Programmable for any Full scale and Offset. Accuracy: 2%
Applications
- Process parameters like Temperature, Pressure, RPM etc., which has 4 -20mA or 0 -20mA output, can be integrated and communicated.
- Single meter solutions for Genset data like Oil level, Temperature with Electrical parameter
Downloads
|