Load Managers
Little Genius & Micro Genius Series
Unique Features

- Wide product spectrum to suit customer requirement. True RMS measurements
- 1 row 6 digit or 3 rows 4 digit display. 4digit resolution for basic & power parameter and 6digits for energy parameter
- Measure 4 quadrant power and energy
- Simultaneous sampling of voltage and current signals ensures better accuracy
- Easy installation and user programmability. User friendly and simple navigation method Reduced operational hassles
- Higher CT/PT ratio programmability. Current primary up to 50kA & Voltage primary up to 99kV. Provides wide range of usability
- Auto scaling and selectable Auto scrolling mode
- Single Phase configuration. Meter provides greater flexibility and wider range of usability
- Larger Full scale programmability. Up to 100 MVA
- OLD Register to store last cleared integrator data
- User Programmable password. Higher security protection
- Wider range and universal auxiliary supply: 80 to 300V AC
- Input Voltage signal (Vin) can be up to 550V. Equipped to handle highly fluctuating voltage signal
- Smart parameter grouping and powerful features
- Optional Pulse Output Or RS 485
- Pre-determined integrator overflows value
- Upgradeable to higher versions
- Positive energy accumulation even in the case of CT reversal
LG 1100 / µG1100
- Displays more than 13 Basic parameters
- VLL, VLN, Current Average and Phase wise
- Autoscaling of Kilo, Mega and Giga
- Auto Scrolling
- Up gradable to higher models
LG3100 / µG3100
- Displays more than 10 Power parameters
- Watts Total and Phase wise
- PF Average and Phase wise
- Active energy Wh, Positive energy accumulation / Rev lock option
- OLD register to store the previously cleared Energy value
- Optional LOAD hours
- Optically isolated RS 485 ( LG Series only ) or Pulse output for Energy management
LG 3110 = LG 1100 + kWh/ µG 3110= µG 1100 + kWh
- Displays more than 15 Basic & Power parameters
- Active energy Wh, Positive energy accumulation / Rev lock option
- OLD register to store the previously cleared Energy value
- Optional LOAD hours
- Optically isolated RS 485 (LG Series only) or Pulse output for Energy management
LG 5110 = LG 1100 + LG 3100/ µG 5110= µG 1100 + LG 3100
- Displays more than 25 Basic, Power and Energy parameters
- Quick and Easy Navigation and Programming
- OLD register to store the previously cleared Energy value
- Optional LOAD hours
- Optically isolated RS 485 (LG Series only) or Pulse output for Energy management
LG 3120 (Dual Energy) / µG 3120
- Directly Replaces Two Energy Meters
- Requires only potential free contact from AMF
- Automatic switching of display based on input
- Displays W Total, PF Average / Phase wise for Load Study and Wh
- Optional LOAD hours
- OLD Registers to store the previously cleared Energy values
- Optically isolated RS 485 (LG Series only) or Pulse output for Energy management
LG1300
- Displays more than 13 Basic parameters
- VLL, VLN, Current Average and Phase wise
- Autoscaling of kilo, Mega and Giga
- Auto Scrolling
- Up gradable to higher models
LG 3300
- Displays more than 10 Power parameters
- Watts Total and Phase wise
- PF Average and Phase wise
- Active energy Wh, Positive energy accumulation / Rev lock option
- OLD register to store the previously cleared Energy value
- Optically isolated RS 485 or Pulse output for Energy management
LG 3310
- Displays more than 15 Basic & Energy parameters
- Active energy Wh, Positive energy accumulation / Rev lock option
- OLD register to store the previously cleared Energy value
- Optically isolated RS 485 or Pulse output for Energy management
- Simultaneous display of Amps/Wh
LG5310 = LG 1300 + LG 3300
- Displays more than 25 Basic, Power and Energy parameters
- Quick and Easy Navigation and Programming
- OLD register to store the previously cleared Energy value
- Optically isolated RS 485 or Pulse output for Energy management
- Simultaneous display of Amps/Wh, W/PF/A
Downloads
|