Little Genius Plus
Little Genius Plus Series is a TRUE RMS meter and applicable to all type of Industries, playing an important role in solutions for Energy management as this series has an unique grouping of parameters, applicable for industrial use.
Rugged construction with shock proof terminals for voltage & current.
- Single / two / three rows
- DC Energy measurement
Common Features
- Accuracy Class 1.0 IEC 61036 / CBIP 88(0.5 Option).
- True RMS measurement.
- Simultaneous sampling of Volts & Amps.
- Energy display programmable-Counter or Resolution based.
- User programmable password protection.
- Auto scrolling.
- Active Energy, positive energy accumulation & reverse Lock.
- Tripping time up to 99 sec with hysteresis of 1%.
- OLD register to store the previously cleared energy value.
Salient Features
3 Row LGP (LGP 5310 & LGP 3399) Features- 3 row 6 digit displays on each row for better readability.
- Life time counter is Uniqueness of LGP 5130 & LGP 5220.
- Programmable relay output maximum 2 (up to 6 threshold parameters) and tripping time up to 99 sec - LGP 5130.
- Two user selectable parameters from basic(VLL / VLN / A / HZ) or W or VA or PF in addition to Wh – LGP 3399.
- 2 row 6 digits display with simultaneous display of two sources of energy.
- Directly replaces 2 nos of energy meters.
- Requires only potential free contact from AMF or 240V.
- Automatic switching of display based on the input source.
- LGP 3220 displays W total, PF average / phase wise for load study with Wh.
- LGP 5220 has separate programmable relay tripping for EB & DG. Also default Load Hours and ON Hours.
- Cost effective multifunctional products.
- Parameters like W, VA, PF phase wise with energy and 1 relay output for power, energy & phase missing in LGP 3100.
- Reduces complexity of stocking as the model LGP 1119 can be used for multiple measurement application. Since, it is field programmable for W / VA / PF / Wh.
Optional Features
Digital output maximum 2 inputs for appropriate models.
Generic Specification
| Specifications | Details | Units | Conditions |
| Accuracy | Class 1(Default) Class 0.5(Option) |
% % |
Reading Reading |
| Burden V or I/ Phase | 0.2 max | VA | per phase |
| Current Input | 0.05 to 6 | Amps | |
| Auxiliary Supply | 80 – 300 | Volts | AC / DC |
| Display Resolution | 1 row - 6 digit 2 row - 6 digit 3 row - 6 digit |
||
| Baud Rate | 2400 to 19200 | bps | |
| Operating Temperature | -10 to +55 14 to 131 |
ºC ºF |
|
| Isolation | 2000 | AC Volts | For 1 minute between communication & other circuits |
Mechanical Specification
| Features | Specifications | Units | Conditions |
| Panel Dimension Bezel | 96 x 96 | mm | |
| Panel Cut-out | 92 +0 -2 X 92 +0 -2 | mm | |
| Depth | 50 | mm | |
| Weight | 250 350 |
Grams | Unpacked Shipping |
Model Selection Guide
| Features | Parameters | LGP 5310 | LGP 3399 | LGP 5220 | LGP 3220 | LGP 3100 | LGP 1119 | |
| Basic | ![]() |
|||||||
| Line to Line Voltage | VLL Avg, VR-Y,VY-B,VB-R | * | * | * | ||||
| Line to Neutral Voltage | VLN Avg, VR-N,VY-N,VB-N | * | * | * | ||||
| Line Current | IAVg, IR,IY,IB | * | * | * | ||||
| Frequency | HZ | * | * | * | ||||
| Power | ||||||||
| Active Power | W Tot, WR, WY, WB | * | * | * | * | * | * | |
| Power Factor | Avg PF, PFR, PFY, PFB | * | * | * | * | * | * | |
| Apparent power | VA Tot, VAr, VAy, VAb | * | * | * | * | |||
| Energy / Integrated | ||||||||
| Active Energy | Wh | * | * | * | * | * | * | |
| Load Hours/ ON Hours | LH | * | * | |||||
| Old Energy | Wh | * | * | * | * | * | * | |
Little Genius Plus 2 Row
Little Genius Plus 3 Row