ISO 9001:2000 and CE certified

eNavigator Series

eNavigator, a sophisticated Power Analyser that enables the user to navigate the full scope of an electrical network & empowers to manage power efficiently. The instrument offers versatile and unmatched features and functions to monitor, profile, record events, control, log data, protect and even check the quality of an electrical system. eNavigator is built to be a one stop shop to meet your energy management needs.

Common Features

  • True RMS Measurement
  • Simultaneous sampling of Volts & Amps
  • Best parameters Grouping/Bright display
  • Available in LED 4 row 6 digits each
  • Neutral current & RPM display
  • User programmable Password protection
  • Auto scaling of Kilo, Mega, Giga and decimal point
  • Clearance and Creepage distance meets UL 508 safety standard
  • Accuracy class 1.0 IEC 61036 / CBIP 88 (0.5 Option)
  • Upgradable to higher versions
  • Field programmable star, delta or single phase configuration
  • Interruption-recording of number of power failures

Salient Features

  • High / Low recording-Voltage, Current, Hz, W, VA, VAr, PF
  • % of Unbalance V & A for all the phases
  • THD for Voltage and Current
  • Individual Harmonics up to 31st level for V & A
  • Ampere hour and PF average
  • Programmable starting current in % of 5A Secondary. Default 0.4%
  • Programmable parameter updates time 1 sec to 5 sec. Default 1 sec
  • Programmable Auto scrolling time 1 sec to 5 sec. Default 5 sec
  • Dynamic communication - user selectable register map
  • Energy display programmable as counter or resolution based
  • Energy resetting @ 999999 K* Multiplication factor
  • Demand updating @ 1 sec

Generic Specification

Specifications Details Units Conditions
Accuracy Class 1(Default)
Class 0.5(Option)
%
%
Reading
FS
Burden V or I/ Phase 0.2 max VA per phase
Current Input 0.05 to 6 Amps  
Auxiliary Supply 80 – 300 Volts AC/DC
Display Resolution 4 row-6 digit    
Baud Rate 600 bps to 19200 bps bps  
Operating Temperature -10 to +55
-14 to 131
ºC
ºF
 
Storage temperature -25 to 70
-13 to 158
ºC
ºF
 
Overload Current 10
50
Amps Continuous
Max for 3 Sec
Isolation 2000 AC Volts For 1 minute between communication & other circuits
Communication Modbus RTU protocol   RS 485
RS 232(Optional)

Mechanical Specification

Features Specifications Units Conditions
Panel Dimension Bezel 96 x 96 mm  
Panel Cut-out 92 +0 -2 X 92 +0 -2 mm  
Depth 50 mm  
Weight 300
400
Grams Unpacked
Shipping

The IEC standards

Standards Applicable
Tests of insulation properties IEC 60060-1
Test of Accuracy requirements IEC 62052-11
Test of electrical requirements IEC 62052-11
Radio interference suppression CISPR 22
Fast transient burst test IEC 61000-4.4
Damped oscillatory waves immunity test IEC 61000-4.12
Test of immunity to electromagnetic RF fields IEC 61000-4.3
Test of immunity to conducted disturbances, induced by radio-frequency fields IEC 61000-4.6
Test of immunity to electrostatic discharges IEC 61000-4.2
Surge immunity test IEC 61000-4.5
Test of the effect of the climatic environments IEC 60068-2
Mechanical Tests IEC 60068-2
Test of protection against penetration of dust and water IEC 60529
Test of resistance to heat and fire IEC 60695-2

Datalog Specification

No of Parameters 1 2 4 9 14 29
No of Records 8400 5600 3360 1680 1120 560

Optional features

  • Dual port communication
  • Data logger maximum 8400 data with time stamp
  • Digital Outputs 4 potential free contacts with programmable time delay
  • Digital Input (Up to 4 inputs)
  • Analog Input voltage (0-1V) /current (0-20mA or 4-20mA), programmable to any full scale value

Model Selection Guide

Features Parameters EN8400 EN8400LM EN8410 EN8410DMC
Basic          
Line to Neutral Vlg VLN Avg, Vr-N,Vy-N,Vb-N * * * *
Line to Line Vlg VLL Avg, Vr-y,Vy-b,Vb-r * * * *
Line Current, Calculated IN IAvg, Ir,Iy,Ib,In * * * *
Neutral Current Computed ANC * * * *
Frequency, RPM (Generator application) HZ, RPM * * * *
V & I Phase Angle Vr,Vy,Vb,Ir,Iy,Ib,IN * * * *
Unbalance V & A %V, %A * * * *
Power          
Active Power W Tot,Wr,Wy,Wb * * * *
Apparent Power VA Tot, VA r,VA y,VA b ** VATot * * *
Reactive Power VAr Tot, VAr r, VAr y, VAr b ** VARTot * * *
Power Factor PF Avg, PFr,PFy,PFb * * * *
Energy / Integrated          
Active Energy (Wh) Wh * * * *
Apparent Power (VAh) VAh * * * *
Reactive Energy (VArh) VArh-Ind, VArh-Cap   * * *
Load Hours, Interruption, Life Timer LH, Interrupt, Life count * * * *
Old Energy, Old Load Hours, Amp Hrs, PF Avg Wh,VAh,VArh Ind/Cap, LH Old, Ah, PF Avg * * * *
Harmonics          
Voltage THD   * * * *
Current THD   * * * *
K factor   * * * *
Events          
Voltage-VLN, LL High/ Low VLN, VLL * * * *
Current High/ Low A * * * *
Frequency High/ Low Hz * * * *
W High/ Low W * * * *
VA High/ Low VA * * * *
VAr High/ Low VAr * * * *
PF High/ Low PF * * * *
Demand Programmable to any one of them        
Active Power (Wh) Watt Hour ** Sliding window 1 relay ** Sliding window 2 relay ** RTC based *** RTC based 4 relay
Apparent Power (VAh) VA Hour ** Sliding window 1 relay ** Sliding window 2 relay ** RTC based *** RTC based 4 relay
Reactive Power (VArh) VAr Hour   ** Sliding window 2 relay ** RTC based *** RTC based 4 relay
Current Average I Avg   ** Sliding window 2 relay ** RTC based *** RTC based 4 relay
Special features          
40A Direct measurement 3 Phase *** *** *** ***
Neutral current measured INM *** *** *** ***
Import / Export(RD) Wh, VAh, VArh Ind/ Cap ** ** ** **
Individual Harmonics V & A upto 31st harmonics   ** ** **

* Default
** Optional feature, no restriction on combination of options
*** Restricted option, all restricted optional combination may not be possible
© 2010 ElMeasure India Pvt Ltd. All Rights Reserved.